fieldcommunicator

Yokogawa AXF100G-E2AH1H-BA11-21B/L2/CH AXF100G Magnetic Flow

description:Yokogawa AXF100G-E2AH1H-BA11-21B/L2/CH AXF100G Magnetic Flowmeter...
BASIC INFO

Yokogawa AXF100G-E2AH1H-BA11-21B/L2/CH AXF100G Magnetic Flowmeter



 




Yokogawa AXF100G-E2AH1H-BA11-21B/L2/CH AXF100G Magnetic Flowmeter

The ADMAG AXF is the magnetic flow meter which has adopted the proven Dual Frequency Excitation. Moreover, the Enhanced Dual Frequency Excitation has been newly added to tackle more severe applications.

The AXF has user-friendly functions; such as an electrode adhesion level diagnosis function, infra-red switches which can be used for setting parameters without opening the case cover, ability to change the direction of electrical connection on the site.Based on FOUNDATION fieldbus specifications, AXF Fieldbus models offer more flexible instrumentation through a higher level communication capability and propose the cost reduction by multi-drop wirings with less cables. FOUNDATION fieldbus is a registered trademark of Fieldbus FOUNDATION.

 

Features of Yokogawa AXF100G-E2AH1H-BA11-21B/L2/CH AXF100G Magnetic Flowmeter

 

 

User-oriented Functionality of Yokogawa AXF100G-E2AH1H-BA11-21B/L2/CH AXF100G Magnetic Flowmeter

 

Fluid Adhesion Level Diagnosis
The amount of insulating material on the electrode is constantly monitored to determine when maintenance should be performed. An optional replaceable electrode is easy to remove and clean.

Easy Setup
The most frequently used parameters are arranged in a group at the top of the display. Infrared switches enable the setting of parameters without opening the cover.

 

Expansion of Product Lineup of Yokogawa AXF100G-E2AH1H-BA11-21B/L2/CH AXF100G Magnetic Flowmeter

 

Improved Accuracy Specification
The standard accuracy is 0.35% of reading. Also available as an option is high accuracy calibration rated at 0.2% of reading.

 

Extra Small Size Flange Type
Flange types are now available in sizes as small as 2.5 mm.

 

Variety of Sanitary Connections
A wider variety of sanitary connections are now available, including Tri-Clamp, ISO, DIN and SMS.

 

Specification of Yokogawa AXF100G-E2AH1H-BA11-21B/L2/CH AXF100G Magnetic Flowmeter

 

AXF
Remote Flowtube

AXF
Integral Flow meter

AXFA14
Converter

AXFA11
Converter

Size

2.5 to 400 mm
(0.1 to 16 inch)
[depends on
specifications]

2.5 to 400 mm
(0.1 to 16 inch)
[depends on
specifications]

Combined with Remote type flowtube
2.5 to 400mm
(0.1 to 16 inch)

Combined with Remote type flowtube (Note)
2.5 to 400m
(0.1 to 16 inch)

Type of Use

General-purpose use,
Ex-proof type,
Sanitary type,
Submersible type

General-purpose use,
Ex-proof type,
Sanitary type

General-purpose use,
Ex-proof type

General-purpose use

Ambient Temp.

-40 to 60 deg.C (-40 to 140 deg.F) [depends on model type]

Accuracy

0.35% of rate (Optional ; 0.2% of rate)

 

Ordering Models of Yokogawa AXF100G-E2AH1H-BA11-21B/L2/CH AXF100G Magnetic Flowmeter

 

AXF002C-D-1-A-E-1-N-AA1-1-2-1-B
AXF002C-E-1-A-E-1-N-AA1-1-2-1-B
AXF002C-F-1-A-E-1-N-AA1-1-2-1-B

AXF002C-D-2-A-E-1-N-AA1-1-2-1-B
AXF002C-E-2-A-E-1-N-AA1-1-2-1-B
AXF002C-F-2-A-E-1-N-AA1-1-2-1-B

AXF002C-D-1-C-E-1-N-AA1-1-2-1-B
AXF002C-E-1-C-E-1-N-AA1-1-2-1-B
AXF002C-F-1-C-E-1-N-AA1-1-2-1-B


AXF002C-D-2-C-E-1-N-AA1-1-2-1-B
AXF002C-E-2-C-E-1-N-AA1-1-2-1-B
AXF002C-F-2-C-E-1-N-AA1-1-2-1-B

AXF002C-D-1-A-H-1-N-AA1-1-2-1-B
AXF002C-E-1-A-H-1-N-AA1-1-2-1-B
AXF002C-F-1-A-H-1-N-AA1-1-2-1-B


 

AXF002C-D-1-A-L-1-N-AA1-1-2-1-B
AXF002C-E-1-A-L-1-N-AA1-1-2-1-B
AXF002C-F-1-A-L-1-N-AA1-1-2-1-B

AXF002C-D-1-A-P-1-N-AA1-1-2-1-B
AXF002C-E-1-A-P-1-N-AA1-1-2-1-B
AXF002C-F-1-A-P-1-N-AA1-1-2-1-B

Yokogawa AXF100G-E2AH1H-BA11-21B/L2/CH AXF100G Magnetic Flowmeter

AXF065G-D-2-A-L-1-N-AA2-1-0-1-B/CH
AXF065G-E-2-A-W-1-N-AA2-1-0-1-B/CH
AXF065G-D-1-A-L-1-N-AA2-1-0-1-B/CH
AXF065G-E-1-A-W-1-N-AA2-1-0-1-B/CH
AXF065G-D-1-A-L-1-N-AA1-1-0-1-B/CH
AXF065G-E-1-A-W-1-N-AA1-1-0-1-B/CH
AXF065G-D-2-U-L-1-N-AA2-1-0-1-B/CH
AXF065G-E-2-U-W-1-N-AA2-1-0-1-B/CH
AXF065G-D-1-U-L-1-N-AA2-1-0-1-B/CH
AXF065G-E-1-U-W-1-N-AA2-1-0-1-B/CH
AXF065G-D-1-U-L-1-N-AA1-1-0-1-B/CH
AXF065G-E-1-U-W-1-N-AA1-1-0-1-B/CH


Yokogawa AXF100G-E2AH1H-BA11-21B/L2/CH AXF100G Magnetic Flowmeter
 

AXF080G-D-2-A-L-1-N-AA2-1-0-1-B/CH
AXF080G-E-2-A-W-1-N-AA2-1-0-1-B/CH
AXF080G-D-1-A-L-1-N-AA2-1-0-1-B/CH
AXF080G-E-1-A-W-1-N-AA2-1-0-1-B/CH
AXF080G-D-1-A-L-1-N-AA1-1-0-1-B/CH
AXF080G-E-1-A-W-1-N-AA1-1-0-1-B/CH
AXF080G-D-2-U-L-1-N-AA2-1-0-1-B/CH
AXF080G-E-2-U-W-1-N-AA2-1-0-1-B/CH
AXF080G-D-1-U-L-1-N-AA2-1-0-1-B/CH
AXF080G-E-1-U-W-1-N-AA2-1-0-1-B/CH
AXF080G-D-1-U-L-1-N-AA1-1-0-1-B/CH
AXF080G-E-1-U-W-1-N-AA1-1-0-1-B/CH

Yokogawa AXF100G-E2AH1H-BA11-21B/L2/CH AXF100G Magnetic Flowmeter

AXF100G-D-2-A-L-1-N-AA2-1-0-1-B/CH
AXF100G-E-2-A-W-1-N-AA2-1-0-1-B/CH
AXF100G-D-1-A-L-1-N-AA2-1-0-1-B/CH
AXF100G-E-1-A-W-1-N-AA2-1-0-1-B/CH
AXF100G-D-1-A-L-1-N-AA1-1-0-1-B/CH
AXF100G-E-1-A-W-1-N-AA1-1-0-1-B/CH
AXF100G-D-2-U-L-1-N-AA2-1-0-1-B/CH
AXF100G-E-2-U-W-1-N-AA2-1-0-1-B/CH


AXF100G-E-1-U-W-1-N-AA2-1-0-1-B/CH
AXF100G-D-1-U-L-1-N-AA1-1-0-1-B/CH
AXF100G-E-1-U-W-1-N-AA1-1-0-1-B/CH

Yokogawa AXF100G-E2AH1H-BA11-21B/L2/CH AXF100G Magnetic Flowmeter

AXF125G-D-2-A-L-1-N-AA2-1-0-1-B/CH
AXF125G-E-2-A-W-1-N-AA2-1-0-1-B/CH
AXF125G-D-1-A-L-1-N-AA2-1-0-1-B/CH
AXF125G-E-1-A-W-1-N-AA2-1-0-1-B/CH
AXF125G-D-1-A-L-1-N-AA1-1-0-1-B/CH
AXF125G-E-1-A-W-1-N-AA1-1-0-1-B/CH
AXF125G-D-2-U-L-1-N-AA2-1-0-1-B/CH
AXF125G-E-2-U-W-1-N-AA2-1-0-1-B/CH
AXF125G-D-1-U-L-1-N-AA2-1-0-1-B/CH
AXF125G-E-1-U-W-1-N-AA2-1-0-1-B/CH
AXF125G-D-1-U-L-1-N-AA1-1-0-1-B/CH
AXF125G-E-1-U-W-1-N-AA1-1-0-1-B/CH

Yokogawa AXF100G-E2AH1H-BA11-21B/L2/CH AXF100G Magnetic Flowmeter

AXF125C-D-2-A-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF125C-E-2-A-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF125C-D-1-A-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF125C-E-1-A-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF125C-D-1-A-L-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF125C-E-1-A-W-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF125C-D-2-U-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF125C-E-2-U-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF125C-D-1-U-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF125C-E-1-U-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF125C-D-1-U-L-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF125C-E-1-U-W-1-N-AA1-1-0-1-B-/FF1-/G12/CH


Yokogawa AXF100G-E2AH1H-BA11-21B/L2/CH AXF100G Magnetic Flowmeter
 

AXF100C-D-2-A-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF100C-E-2-A-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF100C-D-1-A-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF100C-E-1-A-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF100C-D-1-A-L-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF100C-E-1-A-W-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF100C-D-2-U-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF100C-E-2-U-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF100C-D-1-U-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF100C-E-1-U-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF100C-D-1-U-L-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF100C-E-1-U-W-1-N-AA1-1-0-1-B-/FF1-/G12/CH

Yokogawa AXF100G-E2AH1H-BA11-21B/L2/CH AXF100G Magnetic Flowmeter

AXF080C-D-2-A-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF080C-E-2-A-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF080C-D-1-A-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF080C-E-1-A-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF080C-D-1-A-L-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF080C-E-1-A-W-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF080C-D-2-U-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF080C-E-2-U-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF080C-D-1-U-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF080C-E-1-U-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF080C-D-1-U-L-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF080C-E-1-U-W-1-N-AA1-1-0-1-B-/FF1-/G12/CH

Yokogawa AXF100G-E2AH1H-BA11-21B/L2/CH AXF100G Magnetic Flowmeter

AXF065C-D-2-A-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF065C-E-2-A-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF065C-D-1-A-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF065C-E-1-A-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF065C-D-1-A-L-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF065C-E-1-A-W-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF065C-D-2-U-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF065C-E-2-U-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF065C-D-1-U-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF065C-E-1-U-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF065C-D-1-U-L-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF065C-E-1-U-W-1-N-AA1-1-0-1-B-/FF1-/G12/CH

 

 

We are specialized in intelligent instruments, including : control system, transmitters, flow meters,sensors, recorders, analyzers, control valves, controllers, PLC's, etc.
 
We mainly supply YOKOGAWA,WEIDMULLER, ABB, MOELLER, SCHNEIDER ElECTIC,FUJI,OMRON,HONEYWELL,SIEMENS,FLUKE,PEPPERL+FUCHS,HIMA,
Endress+ Hauser etc.

 

Why choose us?
 
1. 100% original product, 100% quality assurance.
If you find a fake. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!
 
2. Varied payment methods.
We adopt T/T, western union and paypal. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!
  
3. SHIPPING:
We can shipping all over the world.via DHL,UPS,Fedex,TNT and EMS etc., the packaging is very safe and strong. if you have any special needs,please notify me.
It will take 3 to 7days to reach in your hands.

Packaging: 
Imported with original packaging or standard export packing.Customize design is acceptable.
 
Contact:
 
HONGKONG XIEYUAN TECH CO., LIMITED

Email:becky@hkxytech.com   Web:www.hkxytech.com
Mobile:+86-15972186287(Whatsapp & Wechat)


Previous:Yokogawa AAI143-H53 AAI143-H50 AAI143-H00 Analog Input Modul Next:Yokogawa AAI543-S00 AAI543-H00 AAI143-S00 AAI143-H00 AAI543